dc.contributor.author |
Mergen, Cristian |
|
dc.contributor.author |
Kunzel, Roseli |
|
dc.contributor.author |
Góes, Evamberto Garcia de |
|
dc.contributor.author |
Cas, Elias Vergílio da |
|
dc.contributor.author |
Alves, Nelson Mendes |
|
dc.contributor.author |
Botelho, Marcel Zago |
|
dc.date.accessioned |
2011-10-01T03:43:03Z |
|
dc.date.available |
2011-10-01T03:43:03Z |
|
dc.date.issued |
2005 |
|
dc.identifier.citation |
MERGEN, C. et al. Dosimetria do sangue irradiado com equipamentos de cobaltoteleterapia. Disciplinarum Scientia. Série Ciências Naturais e Tecnológicas, v. 6, p. 67-77, 2005. Disponível em: <http://sites.unifra.br/Portals/36/tecnologicas/2005/Dosimetria.pdf>. Acesso em: 30 set. 2011. |
pt_BR |
dc.identifier.issn |
1981-2841 |
|
dc.identifier.uri |
http://repositorio.furg.br/handle/1/1063 |
|
dc.description.abstract |
A irradiação do sangue total e dos componentes celulares inativa as células T e elimina os riscos da doença enxerto-versus-hospedeiro associada à transfusão. Pelo menos, 2500 cGy devem ser liberados no plano médio do volume irradiado para garantir a completa inativação dessas células. Neste estudo, realizou-se uma dosimetria no sangue irradiado com equipamento de cobaltoteleterapia, utilizando-se detectores termoluminescentes. Observou-se que são necessários, pelo menos, dois campos paralelos e opostos para promover a homogeneidade na distribuição da dose no volume de sangue irradiado com esses equipamentos. |
pt_BR |
dc.description.abstract |
Irradiation of whole blood and blood product inactivate T-cells and eliminate the risk of transfusion-associated graft-versus-host disease. At least 2500 cGy to be delivered at the middle plane of the irradiated volume to guarantee one complete inactivation of T-cells. In this study, dosimetric procedures was carried out to better determine the spatial distribution of the absorbed dose over the irradiated volume using a cobalt teletherapy unit and termoluminescent detectors. We have observed that at least two parallel-opposed fields to be used to obtain homogeneous dose distribution in the irradiated volume. |
pt_BR |
dc.language.iso |
por |
pt_BR |
dc.rights |
open access |
pt_BR |
dc.subject |
DEVH-AT |
pt_BR |
dc.subject |
Irradiação de sangue |
pt_BR |
dc.subject |
Controle de qualidade |
pt_BR |
dc.subject |
TA-GVHD |
pt_BR |
dc.subject |
Blood irradiation |
pt_BR |
dc.subject |
Quality control. |
pt_BR |
dc.title |
Dosimetria do sangue irradiado com equipamentos de cobaltoteleterapia |
pt_BR |
dc.type |
article |
pt_BR |