Show simple item record

dc.contributor.author Signori, Luis Ulisses
dc.contributor.author Voloski, Fernando Roberto Schütz
dc.contributor.author Kerkhoff, Alessandra Cristina
dc.contributor.author Martini, Léia Brignoni
dc.contributor.author Plentz, Rodrigo Della Méa
dc.date.accessioned 2013-03-22T02:26:01Z
dc.date.available 2013-03-22T02:26:01Z
dc.date.issued 2008
dc.identifier.citation SIGNORI, Luis Ulisses et al. Efeito de agentes térmicos aplicados previamente a um programa de alongamentos na flexibilidade dos músculos isquiotibiais encurtados. Revista Brasileira de Medicina do Esporte, Niterói, v. 14, n. 4, p. 328-331, 2008. Disponível em: <http://www.scielo.br/pdf/rbme/v14n4/v14n4a01.pdf>. Acesso em: 15 dez. 2012. pt_BR
dc.identifier.issn 1517-8692
dc.identifier.uri http://repositorio.furg.br/handle/1/3171
dc.description.abstract A hipotermia e a hipertermia são sugeridas como meios físicos para aumentar a flexibilidade. O objetivo deste estudo foi comparar o efeito desses agentes térmicos aplicados previamente a um programa de alongamentos dos músculos isquiotibiais (ITs) encurtados. Foram selecionados 42 voluntários saudáveis com encurtamento de ITs avaliados pelo teste do Banco de Wells e Dillon (BWD). A amostra foi aleatoriamente dividida em quatro grupos: G1 (controle), n: 10; sete masculinos (M); 23 ± 0,8 anos (a); 23,4 ± 0,7kg/m2; G2 (hipo+alongamentos), n: 12; 9 M; 23 ± 1,2a; 22,8 ± 0,6kg/m2, G3 (hiperalongamentos), n: 12; 10 M; 21,5 ± 0,5a; 23,17 ± 0;6kg/m2; e G4 (alongamentos), n: 8; 6 M; 24,7 ± 1,7a; 23,2 ± 0,4kg/m2. Os grupos G2, G3 e G4 foram submetidos a um programa de alongamentos estáticos, consistindo de 13 sessões (15 min cada) e seguimento de 21 dias. Cada sessão compreendeu uma série de 15 exercícios para cada membro inferior; o tempo de manutenção de cada alongamento foi de 30s e igual tempo de intervalo. Os agentes térmicos foram aplicados através de bolsas térmicas (diâmetro de 30cm) por 15 min, precedendo os alongamentos dos ITs. A temperatura foi controlada para o G2 entre 1º e 4ºC e, para o G3, de 41º a 45ºC. Observou-se que os grupos G2, G3 e G4 apresentaram aumento quantitativo na variação da flexibilidade dos ITs (BWD: G2: 10,8 ± 1,2; G3: 11,5 ± 1,4; G4: 11,07 ± 1,7cm; P < 0,01) em relação ao grupo controle (G1: -0,14cm). Não foram observadas diferenças entre os grupos que aumentaram a flexibilidade. Conclui-se que o aumento da flexibilidade se deve aos alongamentos, e independe da aplicação prévia de hipertermia e/ou hipotermia por condução. pt_BR
dc.description.abstract The hypothermia and hyperthermia are suggested as physical means to increase the flexibility. The objective of this study was to compare the effect of these thermal agents applied previously to a program of muscles stretching isquiotibiais (ITs) shortened. 42 healthy volunteers were selected with shortening of appraised ITs by the sit-and-reach test (BWD). The sample was random divided in 4 groups: G1 (controls) n:10; 7 masculine (M); 23 ± 0,8 years (y); 23,4 ± 0,7kg/m2, G2 (hypo+stretching) n:12; 9M; 23 ± 1,2y; 22,8 ± 0,6kg/m2, G3 (hyper+stretching) n:12; 10M; 21,5 ± 0,5y; 23,17 ± 0;6kg/m2 and G4 (stretching) n:8; 6M; 24,7 ± 1,7y; 23,2 ± 0,4kg/m2. The groups G2, G3 and G4 were submitted to the program of static prolongations, consisting of 13 sessions (15 min each) and continuation within 21 days. Each session consisted of a series of 15 exercises for each inferior member, and the time of maintenance of each prolongation was of 30s and equal time of interval. The thermal agents were applied through thermal bags (diameter of 30cm) for 15 min, preceding the prolongations of ITs, the temperature was controlled for G2 between 1º to 4ºC and G3 41º to 45ºC. It was observed that the groups G2, G3 and G4 presented quantitative in the variation of the flexibility of ITs (BWD: G2: 10,8 ± 1,2; G3: 11,5 ± 1,4; G4: 11,07 ± 1,7cm; P<0,01) in relation to the control group (G1: -0,14cm). Differences were not observed among the groups that increased the flexibility. In conclusion the increase of the flexibility is due to stretching, and this does not depend on the previous application of hyperthermia and/or hypothermia for transport. pt_BR
dc.language.iso por pt_BR
dc.rights open access pt_BR
dc.subject Hipotermia pt_BR
dc.subject Hipertermia pt_BR
dc.subject Flexibilidade pt_BR
dc.subject Exercícios de alongamento muscular pt_BR
dc.subject Hypothermia pt_BR
dc.subject Hyperthermia pt_BR
dc.subject Flexibility pt_BR
dc.subject Muscle stretching exercises pt_BR
dc.title Efeito de agentes térmicos aplicados previamente a um programa de alongamentos na flexibilidade dos músculos isquiotibiais encurtados pt_BR
dc.title.alternative Effect of thermal agents previously applied to a program of prolongations in the flexibility of the shortened isquiotibial muscles pt_BR
dc.type article pt_BR
dc.identifier.doi http://dx.doi.org/10.1590/S1517-86922008000400001 pt_BR


Files in this item

This item appears in the following Collection(s)

:

  • ICB - Artigos publicados em periódicos
  • Show simple item record