Universidade
Federal do Rio Grande
  • Alto contraste


 

EQA - Escola de Química e Alimentos

URI permanente desta comunidadehttps://rihomolog.furg.br/handle/1/1610

Navegar

Resultados da Pesquisa

Agora exibindo 1 - 3 de 3
  • Imagem de Miniatura
    Item
    Pesticide residue determination in groundwaters using solid phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
    (2010) Demoliner, Adriana; Costa, Fabiane Pinho; D'Oca, Marcelo Gonçalves Montes; Primel, Ednei Gilberto; Barbosa, Sergiane Caldas
    Resíduos de quatro agrotóxicos foram determinados durante um ano em águas de poços de uma área agrícola no Sul do Brasil. Os métodos para a separação, identificação e quantificação dos compostos incluíram cromatografia líquida de alta eficiência com detecção por arranjo de diodos (HPLC-DAD) e cromatografia líquida acoplada à espectrometria de massas (LC-ESI-MS/MS). Uma etapa de pré-concentração baseada na extração em fase sólida com cartuchos de 200 mg de C18 foi realizada. Todos os parâmetros analíticos ficaram de acordo com os limites sugeridos para a validação de métodos cromatográficos. Os limites de quantificação para o método, considerando um fator de pré-concentração de 250 vezes, foram 0,2 μg L-1 para todos os analitos por HPLCDAD, 4,0 ng L-1 para o clomazona, carbofurano e tebuconazol e 40,0 ng L-1 para o 2,4-D por LC-ESI-MS/MS. Nas amostras de águas subterrâneas, o 2,4-D não foi detectado e o carbofurano, clomazona e tebuconazol apresentaram concentrações que variaram entre 0,25 e 10,40 μg L-1, 0,20 e 0,82 μg L-1, e 0,20 e 4,16 μg L-1, respectivamente. Os métodos mostraram-se adequados para a determinação de agrotóxicos em águas subterrâneas.
  • Imagem de Miniatura
    Item
    Validação de método para determinação de ácidos orgânicos voláteis em efluentes de reatores anaeróbios empregando cromatografia líquida
    (2011) Cerqueira, Maristela Barnes Rodrigues; Dias, Adriana Neves; Barbosa, Sergiane Caldas; Santana, Fabricio Butierres; D'Oca, Marcelo Gonçalves Montes; Primel, Ednei Gilberto
    This work deals with the method validation for the determination of acetic, propionic and butyric acids (VFAs) in wastewaters from anaerobic reactors by HPLC-DAD. Separation was performed using a C18 column and the mobile phase composition were water pH 3.0 and methanol 90:10 (v/v). The detection and quantification was carried out at 220 nm. The method shows good linearity (r2>0.996), with adequate accuracy (89-102%) and relative standard deviations lower than 18%. The matrix effect was considered low (-4.1, -3.9 and 1.4%). The developed method is fast, simple and cheap; and it was applied in wastewater samples from anaerobic reactor.
  • Imagem de Miniatura
    Item
    Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
    (2010) Barbosa, Sergiane Caldas; Demoliner, Adriana; Costa, Fabiane Pinho; D'Oca, Marcelo Gonçalves Montes; Primel, Ednei Gilberto
    Resíduos de quatro agrotóxicos foram determinados durante um ano em águas de poços de uma área agrícola no Sul do Brasil. Os métodos para a separação, identificação e quantificação dos compostos incluíram cromatografia líquida de alta eficiência com detecção por arranjo de diodos(HPLC-DAD) e cromatografia líquida acoplada à espectrometria de massas (LC-ESI-MS/MS). Uma etapa de pré-concentração baseada na extração em fase sólida com cartuchos de 200 mg de C18 foi realizada. Todos os parâmetros analíticos ficaram de acordo com os limites sugeridos para a validação de métodos cromatográficos. Os limites de quantificação para o método, considerando um fator de pré-concentração de 250 vezes, foram 0,2 μg L-1 para todos os analitos por HPLCDAD, 4,0 ng L-1 para o clomazona, carbofurano e tebuconazol e 40,0 ng L-1 para o 2,4-D por LC-ESI-MS/MS. Nas amostras de águas subterrâneas, o 2,4-D não foi detectado e o carbofurano, clomazona e tebuconazol apresentaram concentrações que variaram entre 0,25 e 10,40 μg L-1, 0,20 e 0,82 μg L-1, e 0,20 e 4,16 μg L-1, respectivamente. Os métodos mostraram-se adequados para a determinação de agrotóxicos em águas subterrâneas.