dc.contributor.author Demoliner, Adriana
dc.contributor.author Costa, Fabiane Pinho
dc.contributor.author D'Oca, Marcelo Gonçalves Montes
dc.contributor.author Primel, Ednei Gilberto
dc.contributor.author Barbosa, Sergiane Caldas
dc.date.accessioned 2014-02-21T19:51:25Z
dc.date.available 2014-02-21T19:51:25Z
dc.date.issued 2010
dc.identifier.citation CALDAS, Sergiane Souza. et al. Pesticide residue determination in groundwaters using solid phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry. Journal of the Brazilian Chemical Society, v. 21, n. 4, p. 642-650, 2010. Disponível em: <http://www.jbcs.sbq.org.br/imagebank/pdf/v21n4a09.pdf>. Acesso em: 12 fev. 2014. pt_BR
dc.identifier.issn 0306-7319
dc.identifier.uri http://repositorio.furg.br/handle/1/4357
dc.description.abstract Resíduos de quatro agrotóxicos foram determinados durante um ano em águas de poços de uma área agrícola no Sul do Brasil. Os métodos para a separação, identificação e quantificação dos compostos incluíram cromatografia líquida de alta eficiência com detecção por arranjo de diodos (HPLC-DAD) e cromatografia líquida acoplada à espectrometria de massas (LC-ESI-MS/MS). Uma etapa de pré-concentração baseada na extração em fase sólida com cartuchos de 200 mg de C18 foi realizada. Todos os parâmetros analíticos ficaram de acordo com os limites sugeridos para a validação de métodos cromatográficos. Os limites de quantificação para o método, considerando um fator de pré-concentração de 250 vezes, foram 0,2 μg L-1 para todos os analitos por HPLCDAD, 4,0 ng L-1 para o clomazona, carbofurano e tebuconazol e 40,0 ng L-1 para o 2,4-D por LC-ESI-MS/MS. Nas amostras de águas subterrâneas, o 2,4-D não foi detectado e o carbofurano, clomazona e tebuconazol apresentaram concentrações que variaram entre 0,25 e 10,40 μg L-1, 0,20 e 0,82 μg L-1, e 0,20 e 4,16 μg L-1, respectivamente. Os métodos mostraram-se adequados para a determinação de agrotóxicos em águas subterrâneas. pt_BR
dc.description.abstract Residues of four pesticides in groundwaters were surveyed during one year in an agricultural area in southern Brazil. The methods for separation, identification and quantification of the compounds included high-performance liquid chromatography with diode array detection (HPLCDAD) and liquid chromatography with electrospray interface tandem mass spectrometry (LC-ESIMS/ MS). A pre-concentration step based on solid-phase extraction with 200 mg C18 cartridges was applied. All the analytical parameters were within the limits suggested for the validation of chromatographic methods. The LOQs for the methods, considering the 250-fold pre-concentration step, were 0.2 μg L-1 for all pesticides by HPLC-DAD, 4.0 ng L-1 for clomazone, carbofuran and tebuconazole and 40.0 ng L-1 for 2,4-D by LC-ESI-MS/MS. In groundwater samples, 2,4-D was not detected, and carbofuran, clomazone and tebuconazole were detected in concentrations ranging from 0.25 to 10.40 μg L-1, from 0.20 to 0.82 μg L-1 and from 0.20 to 4.16 μg L-1, respectively. The methods proved to be adequate for the analysis of pesticides in groundwaters. pt_BR
dc.language.iso eng pt_BR
dc.rights open access pt_BR
dc.subject groundwaters pt_BR
dc.subject pesticides pt_BR
dc.subject HPLC-DAD pt_BR
dc.subject SPE pt_BR
dc.subject LC-MS/MS pt_BR
dc.title Pesticide residue determination in groundwaters using solid phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry pt_BR