Corrosão em vergalhão Thermex em meio contendo cloretos
| dc.contributor.advisor | Biehl, Luciano Volcanoglo | |
| dc.contributor.author | Lorenço, Asafe | |
| dc.date.accessioned | 2025-04-25T20:36:01Z | |
| dc.date.available | 2025-04-25T20:36:01Z | |
| dc.date.issued | 2024 | |
| dc.description | Dissertação (mestrado) | pt_BR |
| dc.description.abstract | Este estudo tem como objetivo investigar os efeitos da corrosão em vergalhões soldáveis expostos em meio contendo cloreto. Durante a pesquisa, amostras amarradas com arame recozido e amostras soldadas com eletrodo revestido foram submetidas a ensaios eletroquímicos, ensaio de perda de massa, observadas através do MEV, microscópio óptico e comparados seus resultados. Foram identificados os principais tipos e fatores que causam a corrosão nos vergalhões Thermex, bem como compreendidos os mecanismos corrosivos envolvidos nesse contexto. O estudo também se dedicou a analisar a inicialização do processo corrosivo induzido por cloretos. Para avaliar a taxa de corrosão e as propriedades elétricas do material, foram realizadas medições do potencial de circuito aberto, espectroscopia de impedância eletroquímica e curvas de polarização. Essas técnicas forneceram informações valiosas sobre a cinética da corrosão e permitiram uma melhor compreensão dos processos corrosivos nos vergalhões Thermex. Foram conduzidas análises da microestrutura formada após a corrosão dos vergalhões, utilizando técnicas como a Espectroscopia de Emissão Óptica, Energia Dispersiva de Raios X (EDS) no Microscópio Eletrônico de Varredura (MEV) e o microscópio óptico. Essas análises permitiram uma caracterização detalhada da estrutura do material antes e após a corrosão, auxiliando na compreensão dos mecanismos corrosivos envolvidos. Os resultados obtidos neste estudo são de grande importância para o avanço do conhecimento na área da corrosão em vergalhões soldáveis expostos em meio contendo cloretos. As informações e diretrizes fornecidas contribuem para o desenvolvimento de práticas de engenharia mais eficazes, visando aumentar a vida útil das estruturas e garantir a segurança das construções costeiras. Os resultados desta pesquisa destacaram o bom desempenho do eletrodo E6013 em relação a ausência de par galvânico com o metal base. A corrosão predominante foi identificada como corrosão por pites e corrosão por frestas com incidência inferior. Verificou-se que as amostras amarradas apresentaram uma perda de massa maior em comparação com as amostras soldadas. Além disso, foi possível prever o tempo em que levaria para o consumo total das amostras soldadas por meio dos declives de Tafel. Medidas de controle e prevenção adequadas, como o uso de revestimentos protetores e a implementação de projetos robustos, juntamente com a monitorização regular da corrosão e a realização de manutenção preventiva, são fundamentais para minimizar os efeitos da corrosão nos vergalhões Thermex e consequentemente prolongar a vida útil das estruturas de concreto armado expostas a um meio contendo cloretos. | pt_BR |
| dc.description.abstract | This study aims to investigate the effects of corrosion on weldable rebar exposed in a chloride-containing medium. During the research, samples tied with annealed wire and samples welded with a coated electrode were subjected to electrochemical tests, mass loss tests, observed through SEM and optical microscope and their results were compared. The main types and factors that cause corrosion in Thermex rebars were identified, as well as the corrosive mechanisms involved in this context were understood. The study was also dedicated to analyzing the initiation of the corrosive process induced by chlorides. To evaluate the corrosion rate and electrical properties of the material, open circuit potential measurements, electrochemical impedance spectroscopy and polarization curves were performed. These techniques provided valuable information on corrosion kinetics and allowed a better understanding of the corrosive processes in Thermex rebars. Analyzes of the microstructure formed after the corrosion of rebars were carried out, using techniques such as Optical Emission Spectroscopy, Energy Dispersive X-rays (EDS) in the Scanning Electron Microscope (SEM) and the optical microscope. These analyzes allowed a detailed characterization of the material structure before and after corrosion, helping to understand the corrosive mechanisms involved. The results obtained in this study are of great importance for the advancement of knowledge in the area of corrosion in weldable rebar exposed in a medium containing chlorides. The information and guidelines provided contribute to the development of more effective engineering practices to increase the useful life of structures and ensure the safety of coastal constructions. The results of this research highlighted the good performance of the E6013 electrode in relation to the absence of galvanic couple with the base metal. The predominant corrosion was identified as pitting corrosion and crevice corrosion with a lower incidence. It was found that the tied samples showed a greater mass loss compared to the welded samples. Furthermore, it was possible to predict the time it would take for the total consumption of the samples welded through the Tafel slopes. Adequate control and prevention measures, such as the use of protective coatings and the implementation of robust designs, together with regular monitoring of corrosion and carrying out preventive maintenance, are essential to minimize the effects of corrosion on Thermex rebars and consequently prolong their life. useful life of reinforced concrete structures exposed to a medium containing chlorides. | pt_BR |
| dc.identifier.citation | LORENÇO, Asafe. Corrosão em vergalhão Thermex em meio contendo cloretos. 2024. 139f. Dissertação (mestrado) - Programa de Pós-Graduação em Engenharia Mecânica, Escola de Engenharia, Universidade Federal do Rio Grande, Rio Grande, 2024. | pt_BR |
| dc.identifier.uri | https://repositorio.furg.br/handle/123456789/12734 | |
| dc.language.iso | por | pt_BR |
| dc.rights | open access | pt_BR |
| dc.subject | Corrosão | pt_BR |
| dc.subject | Vergalhões soldáveis | pt_BR |
| dc.subject | Vergalhões thermex | pt_BR |
| dc.subject | Ambiente marinho | pt_BR |
| dc.subject | Concreto armado | pt_BR |
| dc.subject | Prevenção da corrosão | pt_BR |
| dc.subject | Corrosion | pt_BR |
| dc.subject | Welded walls | pt_BR |
| dc.subject | Thermex walls | pt_BR |
| dc.subject | Marine environment | pt_BR |
| dc.subject | Reinforced concrete | pt_BR |
| dc.subject | Corrosion prevention | pt_BR |
| dc.title | Corrosão em vergalhão Thermex em meio contendo cloretos | pt_BR |
| dc.type | masterThesis | pt_BR |