Show simple item record

dc.contributor.advisor Dias, Daiane
dc.contributor.author Maciel, Juliana Villela
dc.date.accessioned 2020-02-18T11:02:34Z
dc.date.available 2020-02-18T11:02:34Z
dc.date.issued 2018
dc.identifier.citation MACIEL, Juliana Villela. Voltametria de Micropartículas Imobilizadas aplicada à análise direta de cosméticos e produtos de cuidado pessoal para a determinação de compostos orgânicos e chumbo. 2018. 139 f. Tese (Doutorado em Química Tecnológica e Ambiental) – Escola de Química e Alimentos. Universidade Federal do Rio Grande, Rio Grande. pt_BR
dc.identifier.uri http://repositorio.furg.br/handle/1/8313
dc.description.abstract Neste trabalho é proposto o desenvolvimento de três novos eletrodos com base na técnica de Voltametria de Micropartículas Imobilizadas (VIM) combinada à imobilização por drop coating. Uma nova arquitetura baseada na imobilização da amostra na presença de filmes condutores contendo polímeros sobre a superfície do eletrodo de carbono vítreo (GCE) assim como imobilização em eletrodo de pasta de carbono (CPE) foi aplicada neste trabalho. No primeiro eletrodo desenvolvido, partículas de hidroquinona (HQ) foram imobilizadas no filme de quitosana (CTS) reticulada com epicloridrina (ECH) contendo nanopartículas de carbon black (CB) sobre o GCE. O eletrodo HQ(imob.)-CB-CTS-ECH/GCE foi aplicado à determinação de HQ em cremes dermatológicos por Voltametria de Pulso Diferencial (DPV), o qual apresentou um limite de detecção (LOD) de 0,045 ng. A determinação de eugenol (EU) em óleos de cravo foi feita por Voltametria de Onda Quadrada utilizando um GCE modificado com filme de dihexadecil hidrogenofosfato (DHP) contendo CB e padrão de EU imobilizado (EU(imob.)-CB-DHP/GCE), o qual apresentou um LOD de 0,13 ng. Por fim, foi proposto o terceiro eletrodo (Pb(imob.)/CPE) através da imobilização do padrão de Pb sobre a superfície de um CPE, o qual foi utilizado para determinação de Pb em tinturas capilares por DPV, apresentando um LOD de 4 ng. Os eletrodos desenvolvidos mostraram-se adequados, em termos de repetibilidade, estabilidade e seletividade. A VIM combinada a imobilização por drop coating forneceu procedimentos com respostas rápidas e resultados confiáveis com baixos limites de detecção e boa precisão. pt_BR
dc.description.abstract In this work was proposed the development of three new electrodes based on the Voltammetry of Immobilized Microparticles (VIM) technique combined with immobilization by drop coating. A new architecture based on the sample immobilization in the presence of conductive films containing polymers on the surface of the glassy carbon electrode (GCE) as well as immobilization in carbon paste electrode (CPE) was evaluated. In the first electrode developed, hydroquinone particles (HQ) were immobilized in the chitosan cross-linked (CTS) with epichlorohydrin (ECH) film containing carbon black (CB) nanoparticles on the GCE. The electrode HQ(imob.)-CB-CTS-ECH/GCE was applied to HQ determination in dermatological creams by Differential Pulse Voltammetry (DPV) showing a detection limit (LOD) of 0.045 ng. Eugenol (EU) determination in clove oils was performed by Square Wave Voltammetry using a modified GCE with dihexadecyl hydrogenphosphate (DHP) film containing CB and immobilized EU standard (EU(imob.)-CB-DHP/GCE), showing a LOD of 0.13 ng. Finally, in the third electrode (Pb(imob.)/CPE), hair dye samples were immobilized on the CPE surface, which was used to determine Pb by DPV, presenting a LOD of 4 ng. The developed electrodes were adequate in terms of repeatability, stability and selectivity. Hence, VIM combined with drop coating immobilization provides analysis with a fast response and reliable results with low detection limits and good accuracy. pt_BR
dc.language.iso por pt_BR
dc.rights open access pt_BR
dc.subject Voltametria de micropartículas imobilizadas pt_BR
dc.subject Carbon black pt_BR
dc.subject Hidroquinona pt_BR
dc.subject Eugenol pt_BR
dc.subject Chumbo pt_BR
dc.subject Voltammetry of Immobilized Microparticles pt_BR
dc.subject Hydroquinone pt_BR
dc.subject Lead pt_BR
dc.title Voltametria de Micropartículas Imobilizadas aplicada à análise direta de cosméticos e produtos de cuidado pessoal para a determinação de compostos orgânicos e chumbo pt_BR
dc.title.alternative Voltammetry of Immobilized Microparticles applied to the direct analysis of cosmetics and personal care products for organic compounds and lead determinations pt_BR
dc.type doctoralThesis pt_BR


Files in this item

This item appears in the following Collection(s)

:

  • EQA – Doutorado em Química Tecnológica e Ambiental (Teses)
  • Show simple item record