Show simple item record

dc.contributor.advisor Costa, Jorge Alberto Vieira
dc.contributor.advisor Rocha, Luiz Alberto Oliveira
dc.contributor.author Cunha, Daniele Colembergue da
dc.date.accessioned 2016-05-04T20:39:58Z
dc.date.available 2016-05-04T20:39:58Z
dc.date.issued 2009
dc.identifier.citation CUNHA, Daniele Colembergue da. Modelagem, simulação e otimização de biorreatores de leito fixo para fermentação/bioprocesso em estado sólido. 2009. 128 f. Tese ( Doutorado em Engenharia e Ciência de Alimentos) - Escola de Química e Alimentos, Universidade Federal do Rio Grande, Rio Grande, 2009. pt_BR
dc.identifier.uri http://repositorio.furg.br/handle/1/6096
dc.description.abstract Ao contrário dos bioprocessos submersos, que são amplamente utilizados e estudados, bioprocessos em estado sólido (BES) ainda são carentes de estudos de modelagem e simulação, o que aponta para o grande potencial de otimização. A dificuldade no aperfeiçoamento de BES está associada a problemas com a dissipação do calor gerado pelas atividades metabólicas do microrganismo durante o crescimento. Esta dificuldade na transferência de calor dentro do biorreator pode levar a zonas de altas temperaturas, que afetam adversamente a produtividade. A modelagem matemática é uma ferramenta essencial para otimizar bioprocessos. Através de modelos matemáticos é possível otimizar as variáveis operacionais para controle do bioprocesso e também analisar o design do biorreator. A otimização geométrica, de acordo com a Teoria Constructal, visa melhorar o desempenho do biorreator através, por exemplo, de minimizar a temperatura no interior do leito a níveis ótimos para o cultivo. O presente trabalho apresenta projetos de biorreatores para BES, todos com geometria otimizada, obtidos a partir de experimentação numérica, através de um software de computational fluid dynamics (CFD). O modelo matemático utilizado era preditivo e significativo ao nível de confiança de 95%. A otimização geométrica foi apresentada em função das condições operacionais do cultivo. Para o biorreator de coluna e leito fixo com paredes isoladas, foram apresentadas as geometrias ótimas em função da velocidade, da vazão e da temperatura do ar de admissão. Para uma temperatura do ar de admissão de 29,5 ºC, as configurações ótimas ((D/L)opt) variaram entre 1,0 e 2,4 para uma faixa de velocidade de admissão do ar entre 0,003 e 0,006 m s-1 . Relacionando com vazão, as razões mostraram-se ótimas entre 2,2 ≤ (D/L) ≤ 2,6 quando operando sob 3,3 a 3,5 10-5 m3 s-1 . Outro biorreator estudado foi o biorreator modular, composto de módulos elementares com geometria otimizada, sendo adaptável a diferentes escalas de produção e de fácil montagem. As configurações ótimas dos módulos de geometria retangular e seção quadrada foram apresentadas para diferentes volumes de módulos, em função da temperatura e da velocidade do ar de admissão. Foi observado que o volume máximo do módulo sem resfriamento externo é 5 L, para uma velocidade do ar de admissão acima de 0,0045 m s-1 e temperatura inferior ou igual 29,0 ºC O último biorreator proposto foi o biorreator hollow, semelhante a um biorreator de coluna e leito fixo, porém com um duto oco inserido nele. O duto interno tem inúmeros furos perpendiculares às suas paredes, mas sua saída é isolada, permitindo que o ar penetre no meio poroso. A geometria otimizada do biorreator hollow foi apresentada em função da fração de volume do duto interno, da razão entre os diâmetros de entrada e saída do duto interno, da vazão e da temperatura do ar de admissão. Em comparação com o biorreator de coluna convencional de mesmas dimensões e sob mesmas condições operacionais, o biorreator hollow apresentou temperatura máxima mais baixa, demonstrando que o projeto é eficiente para resfriar o meio poroso. Concluiu-se, enfim, no presente trabalho, que a geometria é um parâmetro importante e a sua otimização pode beneficiar o desempenho do biorreator. pt_BR
dc.description.abstract Unlike the submerged bioprocesses, that was wildly used and studied, solid state bioprocess (SSB) are still poorly studied with respect to modeling and simulation, what indicates a big potential for optimization. The difficulty in the BES improvement is associated to problems with the dissipation of heat generated by metabolic activities of microorganisms during growth. This difficulty in transferring heat from the bioreactor could lead to areas with high temperature, which usually affect the productivity adversely. The mathematical modeling is an essential tool for optimizing bioprocesses. Using mathematical models it is possible to optimize operational variables to control the bioprocess and also explore the design of the bioreactor. The geometric optimization, according Constructal Theory, aims to improve the performance of the bioreactor through, for example, minimizing the temperature inside the bed to optimum levels for the bioprocess. The present work presents designs of bioreactors to SSB, all with optimized geometry, obtained from numerical experiments, by computational fluid dynamics (CFD) software. The mathematical model used has been predictive and significant at .95 level of confidence. The geometric optimization was presented as function of operational conditions of the cultivation. For the column fixed bed bioreactor with isolated wall, the optimal configurations are shown as function of flow, velocity and temperature of inlet air. For a inlet air temperature of 29.5 ºC, the optimal configurations ((D/L)opt) varied between 1.0 e 2.4 to a range of inlet velocity between 0.003 e 0.006 m s-1 . Relating with the volumetric flow, the optimal ratios presented between 2.2 ≤ (D/L) ≤ 2.6 when operating under 3.3 a 3.5 10-5 m3 s-1 . Other studied bioreactor was the modular bioreactor, consisting of elementary modules with optimized geometry, being adaptable to different scales of production and easy assembly. The optimal configurations of the modules with rectangular geometry and square section were shown depending on the volume of modules and the temperature and velocity of inlet air. It was observed that the maximum volume of the module without external cooling was 5 L, for a inlet velocity upper 0.0045 m s-1 and temperature smaller or equal to 29.0 ºC. The last proposed bioreactor was the hollow bioreactor, similar to a column fixed bed bioreactor, but with an empty duct inserted on it. The internal duct has innumerable holes perpendicular to its wall (the inlet port), but its end is insulated, allowing the air penetrates into the porous medium. The optimized geometry of hollow bioreactor was presented in function of the volume fraction of internal duct, the ratio between the diameters of inlet and outlet of the internal duct, the flow rate and temperature of the inlet air. Comparing with the conventional column bioreactor with the same configuration and same operational conditions, the hollow bioreactor showed a lower maximum temperature. This demonstrates that the project is efficient at cooling the porous medium. Finally, it was concluded that the geometry is an important parameter and its optimization can benefit the performance of the bioreactor. pt_BR
dc.language.iso por pt_BR
dc.rights open access pt_BR
dc.subject Bioprocessos em estado sólido pt_BR
dc.subject Biorreator pt_BR
dc.subject Otimização geométrica pt_BR
dc.subject Teoria constructal pt_BR
dc.subject Bioreactor pt_BR
dc.subject Constructal theory pt_BR
dc.subject Geometric optimization pt_BR
dc.subject Solid state bioprocess pt_BR
dc.title Modelagem, simulação e otimização de biorreatores de leito fixo para fermentação/bioprocesso em estado sólido pt_BR
dc.type doctoralThesis pt_BR


Files in this item

This item appears in the following Collection(s)

:

  • EQA – Doutorado em Engenharia e Ciência de Alimentos (Teses)
  • Show simple item record